2 Installing and Connecting–Up
2.4 Mounting SIMODRIVE POSMO A
2.4.2

Preparing the cable

Cable for the load
power supply
Cable for
PROFIBUS
(without
electronics
power supply)
2-52
Note
We recommend that connector sleeves are used, but these are not
absolutely necessary.
The outer cable diameter should be maintained in order to guarantee
the IP 54/IP64/IP65 degree of protection.
Use only copper cables with a thermal stability of up to at least 60/75
°
C for connection and wiring. See Figure 2-13
S
2
2 x max. 4 mm
, with or without shield, flexible conductor (finely–stranded)
S
Gland:
PG13.5 (with shield connection) for outdoors ∅ = 6–12 mm
Load cable
6 – 12
(shield
is not
absolutely
required)
Fig. 2-18 Preparing Cable for the load power supply
S
2
2 x 0.35 mm
, with shield
S
Gland:
PG13.5 (with shield connection) for outdoors ∅ = 6–12 mm
PROFIBUS
6 – 12
cable
(without
electronics
power supply)
Fig. 2-19 Preparing the PROFIBUS cable
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
not to scale
10
Shield
120
not to scale
8
Shield
100
E Siemens AG 2013 All Rights Reserved
05.13
08.03
02.99
10