08.06
04.01
02.99
P0954 / 3BA
Additional information on faults/warnings
300W 075W
Min
Standard
The parameter indicates, bit-coded, which supplementary information is available.
The additional information allows to diagnose the faults and warnings exactly.
Bit0 corresponds to Supplementary information 900,
Bit1 corresponds to Supplementary information 901, etc.
Note:
SimoCom A:
Read about possible supplementary information in the online help:
Help ––> Help topics ––> Index ––> 900...911
User Manual:
The description of the faults/warnings, how they can be acknowledged as well as a list of all the
faults/warnings is provided in Section "Fault handling and diagnostics".
Refer to the index entry "Faults/Warnings".
See also P947 and P953.
Available from SW 1.4.
P0964:8 / 3C4
Drive identification
300W 075W
Min
Standard
Indices:
0
Siemens = 42d
1
Drive type
POSMO A 75W/300W = 1201/1202
2
Firmware version
3
Firmware date (year)
4
Firmware date (day/month)
5
No. of axes
6
No. of option modules
7
Gearbox code
Note:
Available from SW 1.4.
P0967 / 3C7
Control word
300W 075W
Min
Standard
0
0
This parameter corresponds to the control signals "control word (STW)".
Note:
The following applies from SW 1.4:
If the Class 2 DP master has control authority, then control is realized via this parameter.
The following applies from SW 2.0:
The meanings of bits 4, 5, 6, 8, 9, 11, 12, 13 and 14 depend on the active operating mode.
SimoCom A:
Please consult the online help for more detailed information:
Help ––> Help topics ––> Index ––> PROFIBUS diagnostics
User Manual:
Bit assignment, refer to Section "Communications via PROFIBUS-DP".
Refer to the index entry "Process data".
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
5.6 Parameters for SIMODRIVE POSMO A
Max
Unit
Max
Unit
(x.yy.zz)
(xxxx decimal)
(ddmm decimal)
(always 1)
(always 0)
Max
Unit
FFFF
Hex
5 Description of the Functions
Data type
Effective
I2
RO
Data type
Effective
V2
RO
Data type
Effective
V2
immed.