08.04
02.99
Connection cover
from the bottom
S1
Setting
S
PROFIBUS
Node address
(station address)
S
PROFIBUS
Terminating resistor
S1
X7
Internal interface
Note:
Screwdriver for terminals (slotted screws)
Where?
Size!
S
X1 and X2
1 (0.5 x 3.5) 0.6...0.8 Nm
S
X3, X4 and X5
0 (0.4 x 2.5) 0.22...0.25 Nm
Fig. 2-15 SIMODRIVE POSMO A connection cover from the bottom
Caution
The screws are not screwed tight into the terminals when the system is
delivered. These must be tightened with the specified tightening
torque, in particular for unused connections as well, otherwise the
screws may fall out under heavy vibration.
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
X3
X1
PROFIBUS–DP
Load power
cable
supply
Input/output
Input/output
B1 A1
X3
X5
X4
B2 A2
X7
X4
PROFIBUS–DP cable
Input/output
Tightening torque!
2 Installing and Connecting–Up
2.3 Connection and wiring overview
X6 /X9
Internal load power supply
Note:
Equipping differs depending on
whether it is a 75 W or 300 W motor
L1
5M
5L+
3L+
X6
X9
3M
X2
X1
1VS
I/Q1
1M
2VS
I/Q2
6M
6L+
2M
4L+
4M
X2
Load power supply
Input/output
X5
3L+
+24 V electronics supply
input (optional)
3M
0 V ground
1VS
Supply 1
I/Q1
Digital input/output 1
1M
0 V ground
2VS
Supply 2
I/Q2
Digital input/output 2
2M
0 V ground
4L+
+24 V electronics power supply
output (optional)
4M
0 V ground
2
2-45