Siemens SIMODRIVE POSMO A User Manual page 252

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

04.01
02.99
Caution
In order to guarantee the degree of protection of SIMODRIVE
POSMO A, after measurements have been made at the analog test
sockets, the cover must be screwed back on.
Standard
The test sockets provide the following signals as standard:
assignment
S
S
Fig. 6-2
Note
With offset = 80
S
S
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
DAU 1 (current actual value)
P33
(ADDRESS: FC32
P34
Shift factor = 7:
ΔV = 1.9 V 8 9 A
ΔV = 1.0 V 8 12 A ––> 300 W motor
8 128
P35
Offset = 80
hex
DAU 2 (speed actual value)
P36
(ADDRESS: FC66
Shift factor = 0: (ΔU = 0.625 V 8 1000 rpm)
P37
8 128
P38
Offset = 80
hex
ΔV = 1.25 V 8 1000 rpm for a shift factor = 1
5 V
Offset
2.5 V
= 80
hex
0 V
Voltage values when measuring the speed actual value
a voltage of 2.5 V is output for "0".
hex
A shift factor change of +1 corresponds to doubling the value
A shift factor change of –1 corresponds to halving the value
6 Fault Handling and Diagnostics
6.3 Analog test outputs
8 64562
)
hex
dec
––> 75 W motor
dec
8 64614
)
hex
dec
dec
ΔV = 0.625 V 8 1000 rpm for a shift factor = 0
2.5 V 8 n
= 0 rpm
act
6
6-251

Advertisement

Table of Contents
loading

Table of Contents