5 Description of the Functions
5.6 Parameters for SIMODRIVE POSMO A
P1427 / 593
Delay time Nsetpoint has elapsed
300W 075W
Min
Standard
0
0
This parameter defines the delay time following which the bit "Ramp-up complete" (ZSW.10) is
output.
If the actual speed value for the specified time is within the tolerance band (P1426), ZSW.10 is
output.
Note:
This parameter is visible in SimoCom A only in operating mode "Speed setpoint" (P930).
Available with software version 2.0 and higher.
5.6.3
Gearbox–dependent parameters, factory default settings
Gearbox–
dependent
parameters
Table 5-10
Gearbox–dependent parameters (factory presetting – default)
Gearboxes
Step-
down
Type
ratio
i
i
Gearbox
Gearbox
75 W motor: Gearbox–dependent parameters (factory default setting)
without gearbox
4.5
8
20.25
Planetary
Planetary
36
gearbox
gearbox
50
126.5625
162
5
Worm
Worm
24
gearbox
gearbox
75
5-230
Max
15000
Depending on the gearbox used, the parameters listed in Table 5-10
are pre–set before the equipment is supplied:
P964:7
P3
Gearbox
Maximum
Gear-
step-
box
down
code
ratio
[mm/min]
2049
1
2050
4.5
2058
8
2059
20.25
2060
36
2061
50
2062
126.5625
2063
162
2064
5
2065
24
2066
75
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
Unit
Data type
ms
T2
P10
P16
Maximum
velocity
overcur-
rent
[A]
30000
18.0
6660
13.33
3750
7.5
1480
18.0
830
11.11
600
8.0
237
9.48
185
7.4
6000
18.0
1250
7.3
400
2.7
E Siemens AG 2013 All Rights Reserved
02.99
04.01
08.06
Effective
immed.
P22
P28
Maximum
Maximum
accel-
current
eration
2
[mm/s
]
[A]
1000
9.0
225
7.8
125
4.6
50
9.0
30
7.9
20
5.6
8
7.8
6
6.0
200
9.0
40
7.3
13
5.3

Advertisement