Siemens SIMODRIVE POSMO A User Manual page 35

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

2 Installing and Connecting–Up
2.2 Electrical system requirements
2-34
Our second recommendation for the 48 V power supply:
Use two SITOP power regulated power supply modules connected in
series to provide the 48 V load power supply.
There are units with current ratings of 10 A, 20 A and 40 A.
L+
SITOP power
M
L+
SITOP power
M
Note:
S
V
Protective diode (blocking voltage: 40 V, current: 3 A)
x
e.g.:
Type SB 540 from RS components Spoerle
Order No.: 183–4337
S
When connected in series, the SITOP power must have the
same current ratings.
Fig. 2-6
Two SITOP power connected in series to double the voltage
Reference:
/KT101/
Regenerative feedback protection when braking the motor (refer to
Chapter 2.2.3)
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
Regener-
24 V
V
1
ative
feedback
protection
(e.g.
DC-PMM)
24 V
V
2
SITOP power, power supplies
Catalog
E Siemens AG 2013 All Rights Reserved
05.13
02.99
48 V
M