Siemens SIMODRIVE POSMO A User Manual page 242

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

04.01
02.99
08.06
708 / P947.8
Speed controller at stop
Cause
The speed controller is at its limit for more than 200 ms.
The required speed is not reached.
The load or friction is too high or the drive is too small.
The current limit (P28, P16) is set too low.
The drive is defective.
Note:
The fault can be changed-over to a warning using P30 (fault suppression).
Remedy
Reduce load.
Increase current limit.
Replace the positioning motor.
Check the drive parameterization.
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Pulse suppression
709 / P947.9
Bus communications
Cause
Bus communications between the master and slave has failed.
The bus cable has been withdrawn or is defective
The EMC faults on the bus cable are too high.
Remedy
Check fieldbus.
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Pulse suppression
710 / P947.10
Hardware watchdog reset
Cause
After a restart, after initiating the CPU monitoring, the positioning motor
goes into a fault condition.
Note:
The following applies from SW 1.3: Afterwards the positioning motor is
no longer referenced.
Remedy
POSMO A 75W :
POSMO A 300W :
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Pulse suppression
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
6 Fault Handling and Diagnostics
6.2 Faults and warnings
Replace the positioning motor.
Replace the drive unit.
6
6-241

Advertisement

Table of Contents