BayStack 470 SDI connection

Media Card SDI connection
Figure 123
Maintenance port location on the Media Card and the
Shielded 50-pin to Serial/ELAN/TLAN adapter
Maintenance port
Configuring a terminal and SDI ports
The SDI port on the Bay Stack 470 can be used for basic configuration and
maintenance. The SDI port is located on the faceplate. It is a DCE port with
a default speed of 9600 bps.
The SDI ports on a Media Card can be used for basic configuration or
maintenance. Figure 123 shows the maintenance port location on the Media
Card and the Shielded 50-pin to Serial/ELAN/TLAN adapter.
The Media Card faceplate provides a female 8-pin mini-DIN serial
maintenance port connection. The maintenance port on the Shielded 50-pin
Communication Server 1000E
Page 285 of 466
Shielded 50-pin to
Serial/ELAN/TLAN
adapter
Installation and Commissioning