Cisco SPS2024 Reference Manual page 347

Cisco systems ethernet switch reference guide
Hide thumbs Also See for SPS2024:
Table of Contents

Advertisement

SNMP Commands
snmp-server v3-host
SPS208G/SPS224G4/SPS2024 Command Line Interface Reference Guide
informs — Indicates that SNMP informs are sent to this host.
noauth — Indicates no authentication of a packet.
auth — Indicates authentication of a packet without encrypting it.
priv — Indicates authentication of a packet with encryption.
port
— Specifies the UDP port of the host to use. If unspecified, the default
UDP port number is 162. (Range: 1-65535)
filtername—
Specifies a string that defines the filter for this host. If
unspecified, nothing is filtered. (Range: 1-30 characters)
seconds —
Specifies the number of seconds to wait for an
acknowledgment before resending informs. If unspecified, the default
timeout period is 15 seconds. (Range: 1-300)
retries
— Specifies the maximum number of times to resend an inform
request. If unspecified, the default maximum number of retries is 3. (Range:
0-255)
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration mode
User Guidelines
A user and notification view are not automatically created. Use the snmp-server
user, snmp-server group and snmp-server view Global Configuration mode
commands to generate a user, group and notify group, respectively.
Example
The following example configures an SNMPv3 host.
Console(config)# snmp-server v3-host 192.168.0.20 john noauth
26
345

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sps224g4Sps208g

Table of Contents