Cisco SPS2024 Reference Manual page 329

Cisco systems ethernet switch reference guide
Hide thumbs Also See for SPS2024:
Table of Contents

Advertisement

RMON Commands
show rmon alarm
SPS208G/SPS224G4/SPS2024 Command Line Interface Reference Guide
User Guidelines
There are no user guidelines for this command.
Example
The following example displays RMON 1 alarms.
Console# show rmon alarm 1
Alarm 1
-------
Field
Value
OID
1.3.6.1.2.1.2.2.1.10.1
Last Sample Value878128
Interval 30
Sample Typedelta
Startup Alarmrising
Rising Threshold8700000
Falling Threshold78
Rising Event1
Falling Event1
Owner
CLI
Field
Alarm
OID
Last Sample Value
Interval
Description
Alarm index.
Monitored variable OID.
The statistic value during the last sampling period.
For example, if the sample type is delta, this value
is the difference between the samples at the
beginning and end of the period. If the sample
type is absolute, this value is the sampled value at
the end of the period.
The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds.
25
327