6.Troubleshooting
the paper has shifted from the center.
[A]: Scale marks for DLT
[B]: Scale marks for A3
[C]: 7 scale marks in 2mm intervals
[D]: Center mark
2.
Change the position of the standard bracket by rotating it 180 degrees as shown below. This makes the
docking bracket easier to slide horizontally. Then reattach the docking bracket to the mainframe.
[A]: Reverse
If paper shifts toward the front
Slide the docking bracket backward by the amount which corresponds to that of the shift, in order to move the
finisher in the same direction.
e.g.: When paper has shifted by 4 mm from the center toward the rear (2 mm/division of the scale), move the
docking bracket backward by 4 mm (2 divisions).
620