4.Replacement and Adjustment
2.
Remove the two pressure springs.
3.
Remove the screws from the left and right frames.
4.
Remove the heating sleeve belt unit [A].
To Clear SC544-02 or SC554-02
•
To clear SC544-02 or SC554-02, attach the new unit detection fuse provided with the heating sleeve belt
360