2.Installation
Code
-
Inquiry, registration attempted without acquiring
12002
Request No.
-
Attempted registration without execution of a
12003
confirmation and no previous registration.
-
Attempted setting with illegal entries for certification
12004
and ID2.
-
@Remote communication is prohibited. The device has
12005
an Embedded RC gate-related problem.
-
A confirmation request was made after the confirmation
12006
had been already completed.
-
The request number used at registration was different
12007
from the one used at confirmation.
-
Update certification failed because mainframe was in
12008
use.
-
The ID2 in the NVRAM does not match the ID2 in the
12009
individual certification.
-
The certification area is not initialized.
12010
Error Caused by Response from GW URL
Code
-2385
Other error
-2387
Not supported at the Service Center
-2389
Database out of service
-2390
Program out of service
-2391
Two registrations for the same mainframe
-2392
Parameter error
-2393
External RCG not managed
-2394
Mainframe not managed
-2395
Box ID for external RCG is illegal.
-2396
Mainframe ID for external RCG is illegal.
-2397
Incorrect ID2 format
-2398
Incorrect request number format
SP descriptions
SP5-816-201 (Remote Service: Regist Status DFU(SSP))
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the external nor embedded RCG device is set.
1: The embedded RCG device is being set. Only Box registration is completed. In this status, this unit cannot
272
Meaning
Meaning
Solution/ Workaround
Obtain a Request Number before
attempting the Inquiry or Registration.
Perform Confirmation before attempting
the Registration.
Check ID2 of the mainframe.
Make sure that "Remote Service" in User
Tools is set to "Do not prohibit".
Execute registration.
Check Request No.
Check the mainframe condition. If the
mainframe is in use, try again later.
Check ID2 of the mainframe.
Initialize the certification area.
Solution/ Workaround
Check the registration condition of the mainframe
Check the ID2 of the mainframe.
Check the Request No.