4.Replacement and Adjustment
Tray 1
Tray 2
Tray 3 (Optional PFU tray 1 or LCT)
Tray 4 (Optional PFU tray 2)
Duplex (side 1)
LCT
Blank Margin
•
After adjusting the Leading Edge Registration and Side Registration settings (see the previous section),
do the Blank Margin Adjustment. To do this, check the values of Margins C and D.
•
If they are not within the specifications (see below), then adjust C and D with SP2-103-001 to -020 as
explained below. Then check Margins A and B again.
A: Trailing Edge Blank Margin
B: Right Edge Blank Margin
C: Leading Edge Blank Margin
D: Left Edge Blank Margin
1.
Check the trailing edge [A], right edge [B], leading edge [C], left edge [D] blank margins, and adjust them
using the following SP modes.
Edge
Leading Edge
Trailing Edge
Left Edge
Right Edge
Duplex: Trailing Edge:
L Size: Plain
428
Tray
SP No.
SP2-103-001
SP2-103-002
SP2-103-003
SP2-103-004
SP2-103-006
SP No.
SP1-002-002
SP1-002-003
SP1-002-004
SP1-002-005
SP1-002-006
SP1-002-007
Adjustment Range
4.2 ± 1.5 mm (Plain, Thin)
More than 0.5 mm
2.0 ±1.5 mm
2.0 +2.5 /-1.5 mm
2.0 ±2.0 mm
Threshold
2 ±1.5 mm