6.Troubleshooting
SC No.
Type
SC No.
Type
SC535-00
D
SC No.
Type
SC540-
D
Fusing/paper Exit Motor: Lock
00
During motor ON, after checking lock signals for 2sec, a High level was detected at least
20 times.
•
•
•
•
•
•
•
•
•
538
Error Name/Error Condition/Major Cause/Solution
•
Motor defective
•
Connector disconnected
•
Harness broken
•
BCU defective
•
Replace the development exhaust fan.
•
Reset the connector.
•
Replace the harness.
•
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Paper Exit Cooling Fan Lock
In the motor ON state, the value of the lock sensor is checked every 100msec.
If a lock signal is not obtained for 50 times consecutively.
•
Motor defective
•
Connector disconnected
•
Harness broken
•
BCU defective
•
Replace the paper exit cooling fan.
•
Reset the connector.
•
Replace the harness.
•
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Motor defective
Connector disconnected
Harness broken
BCU defective
Unit torque increased
Replace the fusing/paper exit motor.
Reset the connector.
Replace the harness.
Replace the BCU.