SC No.
Type
SC No.
Type
SC531-00
D
SC No.
Type
SC533-00
D
SC533-01
D
SC No.
Type
SC534-00
D
Error Name/Error Condition/Major Cause/Solution
•
BCU defective
•
Replace the fusing fan.
•
Reset the connector.
•
Replace the harness.
•
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Development Bearing Cooling Fan Lock
In the motor ON state, the value of the lock sensor is checked every 100msec.
If a lock signal is not obtained for 50 times consecutively.
•
Motor defective
•
Connector disconnected
•
Harness broken
•
BCU defective
•
Replace the development bearing cooling fan
•
Reset the connector.
•
Replace the harness.
•
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
PSU Cooling Fan Lock
Development Bearing Cooling Fan
In the motor ON state, the value of the lock sensor is checked every 100msec.
If a lock signal is not obtained for 50 times consecutively.
•
Motor defective
•
Connector disconnected
•
Harness broken
•
BCU defective
•
Replace the development bearing cooling fan.
•
Reset the connector.
•
Replace the harness.
•
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Development Exhaust Fan
In the motor ON state, the value of the lock sensor is checked every 100msec.
If a lock signal is not obtained for 50 times consecutively.
6.Troubleshooting
537