6.Troubleshooting
SC No.
Type
SC521-
C
Duplex Entrance Motor: Lock
01
SC521-
C
Duplex By-pass Motor: Lock
02
During motor ON, after checking the motor error notification registers (err_velo and
err_posi) for 500msec, the error state of either register was detected at least 5 times.
•
•
•
•
•
•
•
•
•
SC No.
Type
SC522-
C
Paper Exit Motor: Lock
00
During motor ON, after checking the motor error notification registers (err_velo and
err_posi) for 500msec, the error state of either register was detected at least 5 times.
•
•
•
•
•
•
•
•
•
SC No.
Type
SC530-00
D
536
Error Name/Error Condition/Major Cause/Solution
Motor defective
Connector disconnected
Harness broken
BCU defective
Encoder defective
Replace the motor.
Reset the connector.
Replace the harness.
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Motor defective
Connector disconnected
Harness broken
BCU defective
Encoder defective
Replace the motor.
Reset the connector.
Replace the harness.
Replace the BCU.
Error Name/Error Condition/Major Cause/Solution
Fusing Fan Lock
In the motor ON state, the value of the lock sensor is checked every 100msec.
If a lock signal is not obtained for 50 times consecutively.
•
Motor defective
•
Connector disconnected
•
Harness broken