Honda SH300 2006 Manual page 286

Table of Contents

Advertisement

ALTERNATOR/STARTER CLUTCH
RIGHT CRANKCASE COVER
REMOVAL
Remove the following:
– luggage box (page 3-5)
– floor side cover (page 3-8)
– under cover (page 3-9)
– exhaust pipe/muffler (page 3-15)
Drain the engine oil (page 4-11).
Drain the coolant (page 7-7).
Disconnect the alternator 3P connector and CKP
sensor 2P (red) connector.
Remove the wire band from the stay.
Release the alternator/CKP sensor wire from the
wire guide and remove them out of the frame.
Remove the two washer bolts and ignition coil
cover.
Remove the two ignition coil stay washer bolt from
the right crankcase.
13-4
2P CONNECTOR
CLAMP
WIRE
WASHER BOLTS
IGNITION COIL COVER
IGNITION COIL
WASHER BOLTS
3P CONNECTOR
WIRE BAND