FUEL SYSTEM (PGM-FI)
MIL 21 BLINKS (O
• Before starting the inspection, check for loose or
poor contact on the O
recheck the MIL blinking.
1. O
Sensor Open Circuit Inspection
2
Turn the ignition switch OFF.
Connect the test harness to the ECM 33P connec-
tor (page 6-14).
Disconnect the O
Check the continuity between the test harness
terminal and the O
the wire harness side.
Connection: A3 – Black/Orange
Is there continuity?
YES
NO
2. O
Sensor Short Circuit Inspection
2
Disconnect the test harness and ECM 33P con-
nector disconnected.
Check for continuity between the O
terminal and ground.
Connection: Black/Orange – Ground
Is there continuity?
YES
NO
6-40
SENSOR)
2
sensor cap connector and
2
sensor cap connector.
2
sensor connector terminal of
2
– GO TO STEP 2.
– Open circuit in Black/Orange wire
– Short circuit in the Black/Orange wire
– GO TO STEP 3.
CAP CONNECTOR (Wire side
of female terminal)
Bl/O
CAP CONNECTOR
(Wire side of
connector
2
female terminal)
TEST HARNESS PIN BOX
Bl/O