Hazardous Applications; Dpf Stationary Regen Only = 0-Disabled; Dpf Stationary Regen Only = 1-Enabled; Service Record - Detroit Diesel MBE 900 Operator's Manual

Hide thumbs Also See for MBE 900:
Table of Contents

Advertisement

When the request is accepted, the DPF
Regeneration Lamp will turn on for
one second and then go off for the
rest of the parked regeneration. The
engine speed will increase to 1200
rpm.
With completion of regeneration, the
following should occur:
□ The HEST lamp will remain
illuminated until the exhaust
outlet temperature is below 525°C
(977°F) or the vehicle speed
exceeds 5 mph.
□ The DPF regeneration lamp will
turn off, along with all other
associated warning lamps.
If any of the above requirements are
removed, the engine will return to idle.
To cancel the parked regeneration, the
driver can toggle the Regen Switch
to ON for five seconds. The DPF
Regeneration Lamp will turn on for
one second to show acceptance of the
cancellation request and then return to
the appropriate state as defined by the
current level of soot in the DPF.

Hazardous Applications

The MCM should be configured to
not allow automatically triggered
over-the-road regenerations (DPF
Manual Regen Only Enable =
Enabled).
All information subject to change without notice. (Rev. 04/08)
DDC-SVC-MAN-0040 0704 Copyright © 2008 DETROIT DIESEL CORPORATION
MBE 900 ENGINE 2007 OPERATOR'S GUIDE
NOTE:
This is for hazardous applications only.
There are two CPC options:
□ DPF Stationary Regen Only = 0
Disabled
□ DPF Stationary Regen Only = 1
Enabled
DPF Stationary Regen Only =
0-Disabled — This option allows
the DPF Regeneration Switch to
request a parked regeneration or an
over-the-road regeneration. If the
conditions previously mentioned are
met, a parked regen will be initiated.
If the conditions are not met, then the
over-the-road regeneration will occur.
DPF Stationary Regen Only =
1-Enabled — This option allows
the DPF Regeneration Switch to only
request a parked regeneration. If the
conditions previously mentioned are
met, a parked regen will be initiated.
If the conditions are not met, nothing
will happen.

Service Record

It is mandatory that customers or
distributors maintain a proper record
of the particulate filter servicing and
cleaning. This record is an agent to
warranty considerations. The record
must include information such as: