Output terminals

8.3 Digital outputs

8.3
Digital outputs
Description
Four bi-directional digital outputs (terminal X541) and two relay outputs (terminal X542) are
available. These outputs are, for the most part, freely parameterizable.
Signal flow diagram
Figure 8-2

Delivery condition

Table 8- 5
Digital outputs, delivery condition
Digital output
DO0
DO1
DI/DO8
DI/DO9
DI/DO10
DI/DO11
496
Signal flow diagram: Digital outputs
Terminal
X542: 2.3
X542: 5.6
X541: 2
X541: 3
X541:4
X541: 5
Delivery condition
"Enable pulses"
"No fault"
"Ready to start"