Functions, monitoring and protective functions
9.4 Extended functions
An overview of DDS changeover without position tracking load gear can be found in Chapter
"Referencing (Page 661)", in Section "Instructions for data set changeover".
Table 9- 15
DDS changeover with load gear position tracking
DDS
p0186 (MDS)
p0187 (encoder 1)
p0188 (encoder 2)
p0189 (encoder 3)
p2502 (encoder for
position control)
Mechanical relationships
p2504/p2505/p2506/
p2503
A, B, C and D designate
different mechanical
relationships.
Load gear position
tracking
Table 9- 16
DDS changeover response
DDS
Changeover response
0
-
1
Switchover during pulse inhibit or operation has no effect
2
Encoder adjustment and referencing bit are reset. Position tracking for EDS0 is no longer calculated, and must
be re-adjusted when switching back to DDS0.
3
Position tracking for EDS0 is continued and the referencing bit is reset.
4
Pulse inhibit/operation: Position tracking for EDS0 is continued and the referencing bit is reset.
5
Position tracking for EDS4 is newly initiated and the referencing bit is reset.
the same applies to EDS0.
6
Position tracking for EDS5 is reinitiated and the referencing bit is reset.
same applies for EDS0.
7
MDS changeover alone during pulse inhibit or operation has no effect
8
Pulse inhibit/operation: Referencing bit is reset.
consequence, the actual position value also changes (the offset correction of the position tracking is canceled).
When switching back to DDS0, the position tracking for EDS0 is newly initiated and the referencing bit is
reset.
It only makes sense to switch back to DDS0 without a new adjustment in DDS0 if the user did not make
1)
a new adjustment in DDS8 and the permissible tolerance window (p2722) was not exited.
9
Pulse inhibit/operation: Position tracking for EDS6 is reinitiated and the referencing bit is reset.
switching back to DDS0, the same applies to EDS0.
The referencing bit (r2684.11) is reset for a DDS changeover. If, in the new DDS, the EDS already has an adjusted
1)
encoder, then the referencing bit is set again.
642
0
1
2
0
0
0
EDS0
EDS0
EDS0
EDS1
EDS1
EDS1
EDS2
EDS2
EDS2
Encod-
Encod-
Encod-
er_1
er_1
er_1
A
A
B
Acti-
Acti-
Deac-
vated
vated
tivated
3
4
5
0
0
1
EDS0
EDS0
EDS4
EDS1
EDS3
EDS1
EDS2
EDS2
EDS2
Encod-
Encod-
Encod-
er_2
er_2
er_2
A
A
A
Acti-
Acti-
Acti-
vated
vated
vated
1)
1)
Position tracking for EDS0 is no longer calculated and, as a
1)
Operating Instructions, 12/2018, A5E36652151A
6
7
8
2
3
0
EDS5
EDS0
EDS0
EDS6
EDS1
EDS1
EDS6
EDS2
EDS2
Encod-
Encod-
Encod-
er_1
er_1
er_1
D
A
A
Acti-
Acti-
Deac-
vated
vated
tivated
1)
When switching back to DDS0,
1)
When switching back to DDS0, the
When
1)
Enclosed Drives
9
4
EDS6
EDS0
EDS2
Encod-
er_1
C
Acti-
vated