6.7.4

Acyclic communication

Acyclic communication, as opposed to cyclic communication, means data is transferred only
when an explicit request is made (e.g., in order to read and write parameters).
The "Read data record" and "Write data record" services are available for acyclic
communication.
The following options are available for reading and writing parameters:
● S7 protocol
This protocol uses the STARTER commissioning tool in online operation via
PROFIBUS/PROFINET, for example.
● PROFIdrive parameter channel with the following data records:
– PROFIBUS: Data block 47 (0x002F)
– PROFINET: Data block 47 and 0xB02F as global access, data block 0xB02E as local
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
Description
Actual value of current
Actual torque value
Actual power value
Actual speed value smoothed
Current actual value, smoothed
Torque actual value, smoothed
Power actual value, smoothed
VIK-NAMUR message bit bar
Alarm code
Error code
The DPV1 services are available for master class 1 and master class 2.
access
6.7 Communication according to PROFIdrive
Parameter
r0068[0]
r0080[0]
r0082[0]
r0063[1]
r0068[1]
r0080[1]
r0082[1]
r3113, see table "NAMUR message
bit bar"
r2132
r2131
Operation
Function diagram
FP6714
FP6714
FP6714
FP4715
FP6714
FP6714
FP6714
--
FP8065
FP8060
327