Siemens SINAMICS S150 NEMA Operating Instructions Manual page 336

Converter cabinet units
Hide thumbs Also See for SINAMICS S150 NEMA:
Table of Contents

Advertisement

Operation
6.7 Communication according to PROFIdrive
Error
Meaning
value
0x7A
Parameter %s [%s]: Write access
only in the commissioning state, data
record base configuration
(device: p0009 = 4).
0x7B
Parameter %s [%s]: Write access
only in the commissioning state,
device configuration
(device: p0009 = 1).
0x7C
Parameter %s [%s]: Write access
only in the commissioning state,
device download
(device: p0009 = 29).
0x7D
Parameter %s [%s]: Write access
only in the commissioning state,
device parameter reset
(device: p0009 = 30).
0x7E
Parameter %s [%s]: Write access
only in the commissioning state,
device ready (device: p0009 = 0).
0x7F
Parameter %s [%s]: Write access
only in the commissioning state,
device (device: p0009 not equal to 0).
0x81
Parameter %s [%s] must not be
written during download.
0x82
Transfer of master control is blocked
by BI: p0806.
0x83
Parameter %s [%s]: Requested BICO
interconnection not possible.
0x84
Parameter %s [%s]: Parameter
change inhibited
(refer to p0300, p0400, p0922)
0x85
Parameter %s [%s]: Access method
not defined.
0x87
Write job will not be executed.
0xC8
Below currently valid limit.
0xC9
Above currently valid limit.
0xCC
Write access not permitted.
334
Comment
BICO output does not supply float values, however the
BICO input requires float values.
The write job is rejected because know-how protection is
active.
Modification request for a value that, although within
"absolute" limits, is below the currently valid lower limit.
Modification request for a value that, although within
"absolute" limits, is above the currently valid upper limit
(e.g., specified by the actual converter rating).
Write access is not permitted because an access code is
not available.
Operating Instructions, 12/2018, A5E36652151A
Additional
info
Enclosed Drives