Setpoint channel and closed-loop control
7.4 Vector speed/torque control with/without an encoder
The value specifies the maximum permissible torque whereby different limits can be
parameterized for motor and regenerative mode.
• p0640
• p1520
• p1521
• p1522
• p1523
• p1524
• p1525
• p1530
• p1531
The currently active torque limit values are displayed in the following parameters:
• r0067
• r1526
• r1527
All of the following limits act on the torque setpoint – that is either available at the speed
controller output for closed-loop speed control or as torque input, for closed-loop torque
control. The minimum or the maximum is used for the various limits. This minimum or
maximum is cyclically calculated and is displayed in the following parameters:
• r1538
• r1539
These cyclical values therefore limit the torque setpoint at the speed controller output/torque
input or indicate the instantaneous max. possible torque. If the torque setpoint is limited, then
this is displayed using the following parameters:
• r1407.8
• r1407.9
Function diagrams
FP 6060
FP 6630
FP 6640
484
Current limit
CO: Torque limit, upper/motoring
CO: Torque limit, lower/regenerative
CI: Torque limit, upper/motoring
CI: Torque limit, lower/regenerative
CO: Torque limit, upper/motoring, scaling
CO: Torque limit, lower/regenerative scaling
Power limit, motoring
Power limit, regenerating
Maximum drive output current
Torque limit, upper/motoring without offset
Torque limit, lower/regenerative without offset
Upper effective torque limit
Lower effective torque limit
Upper torque limit active
Lower torque limit active
Torque setpoint
Upper/lower torque limit
Current/power/torque limits
Operating Instructions, 12/2018, A5E36652151A
Enclosed Drives