Functions, monitoring and protective functions
9.3 Drive functions
NOTICE
Material damage when using motors that are not short-circuit proof
When using motors that are not short-circuit proof, activating the external armature short-
circuit braking can damage these motors.
• Only use motors that are short-circuit proof.
• Use suitable resistors for short-circuiting.
Note
Consequences of incorrect parameterization
In case of incorrect parameterization (e.g., induction motor and external armature short-
circuit selected), fault F07906 "Armature short circuit / internal voltage protection:
Parameterization error" is output.
Function diagram
FP 7014
Parameters
• p0300:
• p1230
• p1231
• p1235
• p1236
• p1237
• r1238
• r1239
540
Technology functions - External armature short circuit
Mot type selection
BI: Armature short-circuit/DC braking activation
Armature short-circuit/DC braking configuration
• 1: External armature short-circuit with contactor feedback signal
• 2: External armature short-circuit without contactor feedback signal
BI: External armature short-circuit, contactor feedback signal
External armature short-circuit, contactor feedback signal monitoring time
External armature short-circuit, delay time when opening
CO: External armature short-circuit state
CO/BO: Armature short-circuit/DC braking status word