Functions, monitoring and protective functions
9.4 Extended functions
STOP cams:
• p2568
• p2569
• p2570
• r2684
Jerk limit:
• p2574
• p2575
9.4.7.3
Basic positioner and safe setpoint velocity limitation
If safe speed monitoring (SLS) or the safe direction motion monitoring (SDI) is also to be
used at the same time as the EPOS positioning function, EPOS must be informed about the
activated monitoring limits. Otherwise these speed monitoring limits can be violated by the
EPOS setpoint input. By monitoring the limit value, if violated, the drive is stopped therefore
exiting the intended motion sequence. In this case, the relevant safety faults are output first,
and then the sequential faults created by EPOS.
Using parameter r9733, the safety functions offer EPOS setpoint limiting values, which when
taken into account, prevent the safety limit value being violated.
In order to prevent a safety limit violation by the EPOS setpoint input, you must transfer the
setpoint limit value (r9733) as follows to the maximum speed setpoint of EPOS (p2594):
● p2594[1] = r9733[0]
● p2594[2] = r9733[1]
In this regard you must set the delay time for SLS/SOS (p9551), so that the relevant safety
monitoring function only becomes active after the maximum required time for the speed to be
reduced below the limit. This required braking time is determined by the actual speed, the
jerk limit in p2574 and the maximum delay in p2573.
Parameters
• p2573
• p2574
• p2593
• p2594
• p9351
• p9551
• r9733
660
BI: EPOS STOP cam activation
BI: EPOS STOP cam, minus
BI: EPOS STOP cam, plus
CO/BO: EPOS status word 2
EPOS jerk limitation
BI: EPOS jerk limitation activation
EPOS maximum delay
EPOS jerk limitation
CI: EPOS LU/revolution LU/mm
CI: EPOS maximum speed, externally limited
SI Motion SLS changeover delay time (Motor Module)
SI Motion SLS(SG) changeover delay time (Control Unit)
CO: SI Motion setpoint speed limit effective
Operating Instructions, 12/2018, A5E36652151A