6.13

Communication services and used port numbers

The drive device supports the protocols listed in the following table. The address
parameters, the relevant communication layer as well as the communication role and the
communication direction are specified for each protocol.
This information allows you to match the security measures for the protection of the
automation system to the used protocols (e.g. firewall). As the security measures are limited
to Ethernet and PROFINET networks, no PROFIBUS protocols are listed in the table.
The following table shows the various layers and protocols that are used.
Layers and protocols
Report
Port number
PROFINET protocols
DCP
Not relevant
Discovery and
configuration
protocol
LLDP
Not relevant
Link Layer
Discovery
protocol
MRP
Not relevant
Media
Redundancy
Protocol
PTCP
Not relevant
Precision
Transparent
Clock Protocol
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
(2) Link layer
(4) Transport layer
(2) Ethernet II and
IEEE 802.1Q and
Ethertype 0x8892
(PROFINET)
(2) Ethernet II and
IEEE 802.1Q and
Ethertype 0x88CC
(PROFINET)
(2) Ethernet II and
IEEE 802.1Q and
Ethertype 0x88E3
(PROFINET)
(2) Ethernet II and
IEEE 802.1Q and
Ethertype 0x8892
(PROFINET)
6.13 Communication services and used port numbers
Function
Description
Accessible
DCP is used by PROFINET to determine
nodes,
PROFINET devices and to make basic
settings.
PROFINET
Discovery and
DCP uses the special multicast MAC
configuration
address:
xx-xx-xx-01-0E-CF,
xx-xx-xx = Organizationally Unique
Identifier
PROFINET
LLDP is used by PROFINET to determine
Link Layer
and manage neighborhood relationships
Discovery
between PROFINET devices.
protocol
LLDP uses the special multicast MAC
address:
01-80-C2-00-00-0E
PROFINET
MRP enables the control of redundant
medium
routes through a ring topology.
redundancy
MRP uses the special multicast MAC
address:
xx-xx-xx-01-15-4E,
xx-xx-xx = Organizationally Unique
Identifier
PROFINET
PTC allows a time delay measurements to
be made between RJ45 ports – therefore
send clock and
send cycle synchronization and time
time synchroni-
synchronization.
zation, based
on IEEE 1588
PTCP uses the special multicast MAC
address:
xx-xx-xx-01-0E-CF,
xx-xx-xx = Organizationally Unique
Identifier
Operation