Parameter Settings - Siemens SINAMICS S150 NEMA Operating Instructions Manual

Converter cabinet units
Hide thumbs Also See for SINAMICS S150 NEMA:
Table of Contents

Advertisement

Electrical installation
4.9 Additional connections

Parameter settings

Table 4- 54
Parameter
p0400[0]
p0404[0]
p0404[0].0
p0404[0].1
p0404[0].2
p0404[0].3
p0404[0].4
p0404[0].5
p0404[0].6
p0404[0].8
p0404[0].9
p0404[0].12
p0404[0].13
p0404[0].14
p0404[0].15
p0404[0].16
p0404[0].17
p0404[0].20
p0404[0].21
p0404[0].22
p0404[0].23
p0405[0]
p0408[0]
162
Parameter settings for an 8-pole resolver at the SMC10
Name
Enc type selection
Encoder configuration effective
Linear encoder
Absolute encoder
Multiturn encoder
Track A/B square-wave
Track A/B sinusoidal
Track C/D
Hall sensor
EnDat encoder
SSI encoder
Equidistant zero mark
Irregular zero mark
Distance-coded zero mark
Commutation with zero mark
Acceleration
Track A/B analog
Voltage level 5 V
Voltage level 24 V
Remote sense (only SMC30)
Resolver excit.
Square-wave signal encoder A/B track
Rotary encoder pulse No.
Value
Resolver 4 speed (1004)
800010(hex)
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
0(hex)
4