Adapting the terminal strip

7.3 Digital outputs

7.3
Digital outputs
Digital output terminals
BO: ryyxx.n
Table 7- 3
0
r0052.0
r0052.1
r0052.2
r0052.3
r0052.4
r0052.5
r0052.6
r0052.7
r0052.8
A complete list of the binector outputs is provided in the List Manual.
Table 7- 4
Signal fault via digital output 1.
Advanced settings
You can invert the signal of the digital output using parameter p0748.
For more information, please see the parameter list and the function block diagrams 2230 f
of the List Manual.
78
p0730
p0731
Binector outputs of the converter (selection)
Deactivating digital output
Drive ready
Drive ready for operation
Drive running
Drive fault active
OFF2 active
OFF3 active
Closing lockout active
Drive alarm active
Setpoint/actual value discrepancy
Example:
p0731
r0052.3
52.3
Changing the function of the digital output
Interconnect the digital output with a binector output of your
choice.
Binector outputs are marked with "BO" in the parameter list
of the List Manual.
r0052.9
Process data control
r0052.10
f_actual >= p1082 (f_max)
r0052.11
Alarm: Motor current/torque limit
r0052.12
Brake active
r0052.13
Motor overload
r0052.14
Motor CW rotation
r0052.15
Inverter overload
r0053.0
DC braking active
r0053.2
f_actual > p1080 (f_min)
r0053.6
f_actual ≥ setpoint (f_setpoint)
With Operator Panel
Set p0731 = 52.3
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
In STARTER
Go online with STARTER and
select "inputs/outputs". Change
the output function via the
corresponding screen form.
SINAMICS G120C frequency converter