Electrical installation
4.9 Additional connections
4.9.22
Additional SMC30 Sensor Module (option K52)
Description
With option K50, an SMC30 Sensor Module is included in the cabinet unit. The additional
SMC30 Sensor Module enables reliable actual value acquisition when using Safety
Integrated Extended Functions (requires a license: option K01).
Note
Safety Integrated Function Manual
A detailed description of the full functionality and handling of the Safety Integrated functions
can be found in the accompanying Function Manual. This manual is available as additional
documentation on the customer DVD supplied with the device.
4.9.23

Additional customer terminal block TM31 (option G61)

Description
An interface module TM31 (customer terminal module –A60 or –X65) is already installed as
standard. A second module (–A61) provides the following additional digital and analog
inputs/outputs in the drive system:
● 8 digital inputs
● 4 bidirectional digital inputs/outputs
● 2 relay outputs with changeover contact
● 2 analog inputs
● 2 analog outputs
● 1 temperature sensor input (KTY84-130/PTC)
Inputs and outputs of the second TM31 must be assigned by the customer; default settings
of the terminals are not provided.