Variable Valve Lift Diagnosis Oil Pressure Switch
FUEL INJECTION (FUEL SYSTEMS)
13.Variable Valve Lift Diagnosis
Oil Pressure Switch
A: REMOVAL
1) Remove the collector cover.
2) Disconnect the ground cable from battery.
3) Remove the air intake chamber. <Ref. to
IN(H6DO)-7, REMOVAL, Air Intake Chamber.>
4) Disconnect the connector from variable valve lift
diagnosis oil pressure switch.
5) Remove the variable valve lift diagnosis oil pres-
sure switch.
• LH side
• RH side
B: INSTALLATION
Install in the reverse order of removal.
NOTE:
Apply liquid gasket to variable valve lift diagnosis
oil pressure switch threads.
Liquid gasket:
THREE BOND 1324 (Part No. 004403042) or
equivalent
Tightening torque:
17 N
IN-00203
FU-02136
FU-02137
FU(H6DO)-28
m (1.7 kgf-m, 12.5 ft-lb)