Subaru Legacy 2005 Service Manual page 1206

Hide thumbs Also See for Legacy 2005:
Table of Contents

Advertisement

COOLING
4) Install the mounting bolts of radiator sub fan mo-
tor assembly.
5) Install
the
reservoir
CO(H4DOTC)-30,
INSTALLATION,
Tank.>
6) Install the over flow pipe.
7) Connect the over flow hose.
8) Install the air intake duct.
9) Lift-up the vehicle.
10) Connect the ATF hose to the clip of radiator
sub fan motor assembly.
11) Install the heat shield cover to radiator. (Model
without ATF warmer)
12) Connect the sub fan motor connector (B).
13) Install the under cover.
14) Lower the vehicle.
Radiator Sub Fan and Fan Motor
CO-00292
tank.
<Ref.
to
Reservoir
CO-00250
(B)
CO-00252
CO(H4DOTC)-28
15) Connect the ground cable to battery.
16) Fill engine coolant.
<Ref. to CO(H4DOTC)-13, FILLING OF ENGINE
COOLANT, REPLACEMENT, Engine Coolant.>
17) Install the collector cover.
C: DISASSEMBLY
1) Remove the clip which holds fan motor connec-
tor onto shroud.
2) Remove the nut which holds fan itself onto fan
motor and shroud assembly.
3) Remove the bolts which install fan motor onto
the shroud.
IN-00203
CO-00097
CO-00050