Siprotec compact feeder protection and recloser controller
Hide thumbs Also See for 7SC80:
Table of Contents

Advertisement

Functions
2.1 General
No.
Information
321
Warn Mem. Para.
322
Warn Mem. Oper.
323
Warn Mem. New
335
>GOOSE-Stop
373.3001 HotLineTag int.
373.3002 HotLineTag ext.
444.3003 Bat. Test int.
502
Relay Drop Out
510
Relay CLOSE
545
PU Time
546
TRIP Time
2152
BATTERY INVALID
2155
BAT.CHARGE GOOD
2156
BAT.CHARGE LOW
2157
BATTERY EMPTY
2172
GPS ModuleError
2184
CT LPS mismatch
2186
Error IO board
2240
Multi. routing
2534
HotLineTag act.
2535
>HotLineTag ext
2537
>Start Bat.Test
2538
BatTest aborted
2539
Execut. BatTest
2540
BatTest failed
2541
BatRecov.failed
2596
Test load act.
6009
GPS time ok
6010
GPS antenna ok
6095
>Block Bat Test
6096
Fill Lev1 reach
6097
Fill Lev2 reach
17566
Dist.CFC Src
2.1.3

Power System Data 1

2.1.3.1

Description

The device requires certain data regarding the network and substation so that it can adapt its functions to this
data depending on the application. This may be, for instance, nominal data of the substation and measuring
transformers, polarity and connection of the measured quantities, breaker properties (where applicable), etc.
There are also certain parameters that are common to all functions, i.e. not associated with a specific protec-
tion, control or monitoring function. The following section discusses this data.
48
Type of
Comments
Informa-
tion
OUT
Warn: Limit of Memory Parameter exceeded
OUT
Warn: Limit of Memory Operation exceeded
OUT
Warn: Limit of Memory New exceeded
SP
>GOOSE-Stop
IntSP
Hot Line Tag internal trigger
IntSP
Hot Line Tag external trigger
IntSP
Battery Test internal trigger
SP
Relay Drop Out
SP
General CLOSE of relay
VI
Time from Pickup to drop out
VI
Time from Pickup to TRIP
OUT
Invalid or no ext. battery connected
OUT
Charge of battery is good
OUT
Charge of battery is low
OUT
Charge of battery is insufficient
OUT
GPS Module Error
OUT
CT LoPo/LPS setting mismatch
OUT
Error occurred on IO board
OUT
Several indications routed
OUT
Hot Line Tag is active, no operation
SP
>Hot Line Tag external trigger
SP
>Start of battery test
OUT
Battery test aborted
OUT
Executing Battery test
OUT
Battery test failed
OUT
Battery recovery failed
OUT
Battery test load active
OUT
Device is GPS time synchronized
OUT
GPS antenna is attached correctly
SP
>Block battery test
OUT
Thresh. reached event log fill level 1
OUT
Thresh. reached event log fill level 2
VI
Disturbance CFC Source
SIPROTEC Compact, 7SC80, Manual