Trip Circuit Supervision 74Tc - Siemens 7SC80 Manual

Siprotec compact feeder protection and recloser controller
Hide thumbs Also See for 7SC80:
Table of Contents

Advertisement

Functions
2.12 Monitoring Functions
No.
Information
1840
PhA InrushDet
1841
PhB InrushDet
1842
PhC InrushDet
1843
INRUSH X-BLK
2277
> BLK 46BC
2278
46BC OFF
2279
46BC BLOCKED
2280
46BC ACTIVE
2281
46BC detect. Ia
2282
46BC detect. Ib
2283
46BC detect. Ic
2284
46BC detect. Va
2285
46BC detect. Vb
2286
46BC detect. Vc
2287
Pos. CT in D1
2288
Pos. CT in D2
2289
Pos. VT in D1
2290
Pos. VT in D2
2530
60VTS Alarm
2531
>BLOCK 60VTS
2532
>BLOCK 60CTS
2533
60CTS Alarm
6509
>FAIL:FEEDER VT
6510
>FAIL: BUS VT
7556
InRush OFF
7557
InRush BLK
7558
InRush Gnd Det
7563
>BLOCK InRush
7564
Gnd InRush PU
7565
Ia InRush PU
7566
Ib InRush PU
7567
Ic InRush PU

Trip Circuit Supervision 74TC

2.12.2
The 7SC80 device features an integrated trip circuit supervision. Depending on the number of available binary
inputs (not connected to a common potential), supervision with one or two binary inputs can be selected. If
the allocation of the required binary inputs does not match the selected supervision type, then a message to
this effect is generated (
Applications
When using two binary inputs, malfunctions in the trip circuit can be detected under all circuit breaker
conditions.
When only one binary input is used, malfunctions in the circuit breaker itself cannot be detected.
242
Type of
Comments
Informa-
tion
OUT
Phase A inrush detection
OUT
Phase B inrush detection
OUT
Phase C inrush detection
OUT
Cross blk: PhX blocked PhY
SP
>Block Broken Conductor Monitor
OUT
Broken Conductor is OFF
OUT
Broken Conductor is BLOCKED
OUT
Broken Conductor is ACTIVE
OUT
BC detected from Ia measurement
OUT
BC detected from Ib measurement
OUT
BC detected from Ic measurement
OUT
BC detected from Va measurement
OUT
BC detected from Vb measurement
OUT
BC detected from Vc measurement
OUT
Position CT in direction D1
OUT
Position CT in direction D2
OUT
Position VT in direction D1
OUT
Position VT in direction D2
OUT
60VTS Alarm
SP
>BLOCK 60VTS
SP
>BLOCK 60CTS
OUT
60CTS Alarm
SP
>Failure: Feeder VT
SP
>Failure: Busbar VT
OUT
InRush OFF
OUT
InRush BLOCKED
OUT
InRush Ground detected
SP
>BLOCK InRush
OUT
Ground InRush picked up
OUT
Phase A InRush picked up
OUT
Phase B InRush picked up
OUT
Phase C InRush picked up
74TC ProgFail ).
SIPROTEC Compact, 7SC80, Manual
E50417-G1140-C486-A8, Edition 07.2017