Functions, Settings, Information
F.2 Settings
Addr. Parameter
3121A 50Ns T DROP-OUT
3122
67Ns-1 DIRECT.
3123
RELEASE DIRECT.
3123
RELEASE DIRECT.
3124
PHI CORRECTION
3125
MEAS. METHOD
3126
RESET DELAY
3130
PU CRITERIA
3131
M.of PU TD
3144
51Ns IEC CURVE
3145
51Ns ANSI CURVE
3146
51Ns Drop-out
3150
50Ns-2 Vmin
3150
50Ns-2 Vmin
3151
50Ns-2 Phi
3152
50Ns-2 DeltaPhi
3153
50Ns-1 Vmin
3153
50Ns-1 Vmin
3154
50Ns-1 Phi
3155
50Ns-1 DeltaPhi
4001
FCT 46
4002
46-1 PICKUP
4003
46-1 DELAY
4004
46-2 PICKUP
664
Function
C
Setting Options
Sens. Gnd Fault
0.00 .. 60.00 sec
Sens. Gnd Fault
Forward
Reverse
Non-Directional
Sens. Gnd Fault 1A
0.001 .. 1.200 A
5A
0.005 .. 6.000 A
Sens. Gnd Fault 1A
0.05 .. 30.00 A
5A
0.25 .. 150.00 A
Sens. Gnd Fault
-45.0 .. 45.0 °
Sens. Gnd Fault
COS φ
SIN φ
Sens. Gnd Fault
0 .. 60 sec
Sens. Gnd Fault
Vgnd OR INs
Vgnd AND INs
Sens. Gnd Fault
1.00 ..
20.00 MofPU; ∞
0.01 .. 999.00 TD
Sens. Gnd Fault
Normal Inverse
Very Inverse
Extremely Inv.
Long Inverse
Sens. Gnd Fault
Very Inverse
Inverse
Short Inverse
Long Inverse
Moderately Inv.
Extremely Inv.
Definite Inv.
Sens. Gnd Fault
Disk Emulation
Instantaneous
Sens. Gnd Fault
0.4 .. 50.0 V
Sens. Gnd Fault
10.0 .. 90.0 V
Sens. Gnd Fault
-180.0 .. 180.0 °
Sens. Gnd Fault
0.0 .. 180.0 °
Sens. Gnd Fault
0.4 .. 50.0 V
Sens. Gnd Fault
10.0 .. 90.0 V
Sens. Gnd Fault
-180.0 .. 180.0 °
Sens. Gnd Fault
0.0 .. 180.0 °
46 Negative
OFF
Seq
ON
46 Negative
1A
0.10 .. 3.00 A
Seq
5A
0.50 .. 15.00 A
46 Negative
0.00 .. 60.00 sec; ∞ 1.50 sec
Seq
46 Negative
1A
0.10 .. 3.00 A
Seq
5A
0.50 .. 15.00 A
Default Setting
Comments
0.00 sec
50Ns Drop-Out Time
Delay
Forward
67Ns-1 Direction
0.010 A
Release directional
element
0.050 A
0.50 A
Release directional
element
2.50 A
0.0 °
Correction Angle for Dir.
Determination
COS φ
Measurement method for
Direction
1 sec
Reset Delay
Vgnd OR INs
Sensitive Ground Fault
PICKUP criteria
Multiples of PU Time-Dial
Normal Inverse
IEC Curve
Very Inverse
ANSI Curve
Disk Emulation
Drop-out characteristic
2.0 V
50Ns-2 minimum voltage
10.0 V
50Ns-2 minimum voltage
-90.0 °
50Ns-2 angle phi
30.0 °
50Ns-2 angle delta phi
6.0 V
50Ns-1 minimum voltage
15.0 V
50Ns-1 minimum voltage
-160.0 °
50Ns-1 angle phi
100.0 °
50Ns-1 angle delta phi
OFF
46 Negative Sequence
Protection
0.10 A
46-1 Pickup
0.50 A
46-1 Time Delay
0.50 A
46-2 Pickup
2.50 A
SIPROTEC Compact, 7SC80, Manual
E50417-G1140-C486-A8, Edition 07.2017