Technical Data Power Electronics - Siemens SIRIUS 3RW44 Manual

Hide thumbs Also See for SIRIUS 3RW44:
Table of Contents

Advertisement

9.3.2 Technical Data Power Electronics

Type
Power electronics
Rated operational voltage for inline circuit
Tolerance
Rated operational voltage for inside-delta circuit
Tolerance
Rated frequency
Tolerance
Continuous operation at 40 °C (% of I
Minimum load (% of set motor current I
Maximum conductor length between soft starter and motor
Permissible installation height
Permissible mounting position
Permissible ambient temperature
Operation
Storage
Degree of protection
Type
Power electronics
Rated operational current I
e
Load rating with rated operational current I
• Acc. to IEC and UL/CSA for individual mounting
at 40/50/60 °C, AC-53a
Smallest adjustable operational current I
For the motor overload protection
Power loss
• In operation after completed soft starting with uninterrupted rated
operational current (40 °C) approx.
• During starting with current limit set to 350 %
Permissible rated motor current and starts per hour
• Normal starting (Class 5)
1)
I
- Rated motor current
, starting time 5 s
M
2)
- Starts per hour
1)3)
I
- Rated motor current
, starting time 10 s
M
2)
- Starts per hour
• Normal starting (Class 10)
1)
I
- Rated motor current
, starting time 10 s
M
2)
- Starts per hour
1)3)
I
- Rated motor current
, starting time 20 s
M
2)
- Starts per hour
• Normal starting (Class 15)
1)
I
- Rated motor current
, starting time 15 s
M
2)
- Starts per hour
1)3)
I
- Rated motor current
, starting time 30 s
M
2)
- Starts per hour
• For heavy starting (Class 20)
1)
I
- Rated motor current
, starting time 20 s
M
2)
- Starts per hour
1)3)
I
- Rated motor current
, starting time 40 s
M
2)
- Starts per hour
• For very heavy starting (Class 30)
1)
I
- Rated motor current
, starting time 30 s
M
2)
- Starts per hour
1)3)
I
- Rated motor current
, starting time 60 s
M
2)
- Starts per hour
SIRIUS 3RW44 manual
GWA 4NEB 535 2195-02 DS 02
)
e
)
M
e
M
I
(40 °C)
M
1)
Current limit on soft starter set to 350 % I
2)
For intermittent duty S4 with ON period = 70 %, T
operating frequencies do not apply for automatic mode.
3)
Maximum adjustable rated motor current I
3RW44 ..-.BC.4
V
200 ... 460 AC
%
-15/+10
V
200 ... 400 AC
%
-15/+10
Hz
50 ... 60
±10
%
%
115
%
8
m
200
m
4000 (derating from 1000); higher on request
22.5° 22.5°
90°
90°
°C
0 ... +60; (derating from +40)
°C
-25 ... +80
IP00
3RW44 22
3RW44 23
29
36
A
29/26/23
36/32/29
A
5
7
W
8
10
W
400
470
A
29
36
1/h
41
34
A
29
36
1/h
20
15
A
29
36
1/h
20
15
A
29
36
1/h
10
6
A
29
36
1/h
13
9
A
29
36
1/h
6
4
A
29
36
1/h
10
6
A
29
36
1/h
4
2
A
29
36
1/h
6
4
A
29
36
1/h
1.8
0.8
.
M
= 40 °C, stand-alone installation vertical. The quoted
u
, dependent on CLASS setting.
M
General Technical Data
3RW44 ..-.BC.5
3RW44 ..-.BC.6
400 ... 600 AC
400 ... 690 AC
-15/+10
-15/+10
400 ... 600 AC
400 ... 600 AC
-15/+10
-15/+10
3RW44 24
3RW44 25
3RW44 26
47
57
77
47/42/37
57/51/45
77/68/59
9
11
15
32
36
45
600
725
940
47
57
77
41
41
41
47
57
77
20
20
20
47
57
77
20
20
20
47
57
77
10
10
8
47
57
77
13
13
13
47
57
77
6
6
6
47
57
73
10
10
10
47
57
73
4
5
1.8
44
57
65
6
6
6
44
57
65
3.3
1.5
2
3RW44 27
93
93/82/72
18
55
1160
93
41
93
20
93
20
93
8
93
13
93
6
88
10
88
0.8
77
6
77
1
9-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents