O2: Digital Operator Keypad Functions; O3: Copy Function - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
Frequency Reference and
o1-14
Frequency Related Monitor
(3106)
Custom Units 2
Frequency Reference and
o1-15
Frequency Related Monitor
(3107)
Custom Units 3
<1> Default setting is dependent on parameter o1-03, Digital Operator Display Selection.
<2> Available in drive software versions PRG: 8503 and later.
u

o2: Digital Operator Keypad Functions

No.
(Addr.
Name
Hex)
o2-01
LO/RE Key Function
(505)
Selection
o2-02
STOP Key Function
(506)
Selection
o2-03
User Parameter Default
(507)
Value
o2-04
Drive Model Selection
(508)
o2-05
Frequency Reference
(509)
Setting Method Selection
Operation Selection when
o2-06
Digital Operator is
(50A)
Disconnected
o2-07
Motor Direction at Power
(527)
Up when Using Operator
o2-20
Operator RUN Save at
(81E)
Power Loss
u

o3: Copy Function

No.
(Addr.
Name
Hex)
o3-01
Copy Function Selection
(515)
o3-02
Copy Allowed Selection
(516)
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Description
Sets the second character of the customer-specified unit display when o1-03
is set to 3 and o1-09 is set to 24.
Sets the third character of the customer-specified unit display when o1-03 is
set to 3 and o1-09 is set to 24.
Description
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
0: No change.
1: Set defaults. Saves parameter settings as default values for a User
Initialization.
2: Clear all. Clears the default settings that have been saved for a User
Initialization.
Enter the drive model. Setting required only if installing a new control board. Default:
0: ENTER key must be pressed to enter a frequency reference.
1: ENTER key is not required. The frequency reference can be adjusted using
the up and down arrow keys only.
0: The drive continues operating if the digital operator is disconnected.
1: An oPr fault is triggered and the motor coasts to stop.
This parameter requires assigning drive operation to the digital operator.
0: Forward
1: Reverse
When running during a power loss, the Run command is issued via the digital
operator and the Run state is saved to the EEPROM.
When power is restored, the Run command is automatically applied if the
LOCAL/REMOTE or FREF conditions have not changed in the drive.
0: Disabled
1: Enabled
Description
0: No action
1: Read parameters from the drive, saving them onto the digital operator.
2: Copy parameters from the digital operator, writing them to the drive.
3: Verify parameter settings on the drive to check if they match the data saved
on the operator.
0: Read operation prohibited
1: Read operation allowed
B.11 o: Operator-Related Settings
Values
Default: 41
Range: 30 to 7A
Default: 41
Range: 30 to 7A
Values
Default: 1
Range: 0, 1
Default: 1
Range: 0, 1
Default: 0
Range: 0 to 2
Determined by
drive capacity
Default: 0
Range: 0, 1
Default: 1
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Values
Default: 0
Range: 0 to 3
Default: 0
Range: 0, 1
Page
269
269
Page
270
270
270
271
271
271
271
271
Page
272
272
B
471