A.4 Drive Derating Data
u

Rated Current Depending on Carrier Frequency

The table below shows the drive output current depending on the carrier frequency settings.
n
Normal Duty Rating (ND)
The 2 kHz values shown for ND in
the carrier frequency above 2 kHz will reduce the ND rated output current of the drive as shown in
Drive Model
2A0004
2A0006
2A0008
2A0010
2A0012
2A0018
2A0021
2A0030
2A0040
2A0056
2A0069
2A0081
2A0110
2A0138
Drive Model
2A0169
2A0211
2A0250
2A0312
2A0360
2A0415
Drive Model
4A0002
4A0004
4A0005
4A0007
4A0009
4A0011
4A0018
4A0023
4A0031
426
Table A.33
are equal to the drive rated current shown on the drive nameplate. Increasing
Table A.31 Three-Phase 200 V Class Carrier Frequency and Current Derating
2 kHz
3.5
6
8
9.6
12
17.5
21
30
40
56
69
81
110
138
2 kHz
169
211
250
312
360
415
Table A.32 Three-Phase 400 V Class Carrier Frequency and Current Derating
2 kHz
2.1
4.1
5.4
6.9
8.8
11.1
17.5
23
31
Three-Phase 200 V Class
Rated Current [A]
Normal Duty Rating (ND)
Three-Phase 200 V Class
Rated Current [A]
Normal Duty Rating (ND)
Three-Phase 400 V Class
Rated Current [A]
Normal Duty Rating (ND)
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Table
8 kHz
3.2
5
6.9
8
11
14
17.5
25
33
47
60
75
85
115
5 kHz
145
180
215
283
346
415
8 kHz
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18
24
A.33.
15 kHz
2.56
4
5.5
6.4
8.8
11.2
14
20
26.4
37.6
48
53
60
81
10 kHz
116
144
172
226
277
332
15 kHz
1.1
2
2.9
3.3
4.3
5.5
8.9
10.8
14.4

Hide quick links: