YASKAWA P1000 Technical Manual page 69

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

Terminals -, +1, +2, B1, B2 are
for connection options. Never
connect power supply lines to
these terminals
Main
Fuse
Three-Phase
Switch
Power Supply
R
200 to 600 V
S
50/60 Hz
T
(Depending on
model capacity)
Models 4A0930 and 4A1200
are compatible with
12-Pulse Rectification
Multi-function
digital inputs
(default setting)
Sink / Source mode
selection wire link
(default: Sink)
2 k
Multi-function
analog/pulse
train inputs
MEMOBUS/Modbus comm.
RS-422/RS-485
max. 115.2 kBps
(max. 150 mA)
<1> Remove the jumper when installing a DC link choke. Models 2A0110 to 2A0415 and 4A0058 to 4A1200 come with a built-in
DC link choke.
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
DC link choke
(option)
U
U
Jumper
+
+
2
Main Circuit
R/L1
EMC
S/L2
Filter
T/L3
Control Circuit
S 1
Forward Run / Stop
Reverse Run / Stop
S 2
External fault
S 3
S 4
Fault reset
S 5
Multi-speed step 1
Multi-speed step 2
S 6
Jog speed
S 7
S 8
External Baseblock
SN
SC
SP
<4>
+
<5>
24 V
Shield ground terminal
RP
Pulse Train Input (max 32 kHz)
<6>
+
V
Power supply +10.5 Vdc, max. 20 mA
A 1
Analog Input 1 (Frequency Reference Bias)
0 to +/-10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
A 2
Analog Input 2 (Frequency Reference Bias)
0 to +10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
A 3
Analog Input 3 (Aux. Frequency Reference)
0 to +/-10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
AC
0 V
Note: When A1 & A3 using current input
Resolution = 10 bit plus sign
Termination resistor
(120 , 1/2 W)
+
+
R
R
-
-
+
+
S
S -
IG
+24 Vdc
+
24V
Transducer
Supply
SN
twisted-pair shielded line
shielded line
Figure 3.1 Drive Standard Connection Diagram (example: model 2A0040)
<1>
X
X
Braking resistor
(option)
<2>
+
+
1
B 1
B 2
P1000 Drive
<3>
Option board
connectors
CN5-C
CN5-B
CN5-A
Terminal board
jumpers and switches
DIP Switch S2
Off
On
Term. Res. On/Off
Jumper S1
V
A1/A2/A3 Volt./Curr.
I
Selection
A1 A2 A3
Jumper S5
V
AM/FM Volt./Curr.
Selection
I
FM
AM
<7>
<8>
DIP
Switch S2
<9>
<11>
control circuit terminal
3.2 Standard Connection Diagram
<12>
FU
FV
M
FW
Cooling fan
U
U/T 1
V
V/T 2
M
W
3
W/T
Ground
MA
Fault output
MB
250 Vac, max. 1 A
30 Vdc, max 1 A
MC
(min. 5 Vdc, 10 mA)
MD
Multi-function relay output (Speed Agree H2-03)
250 Vac, max. 1 A
ME
30 Vdc, max 1 A
MF
(min. 5 Vdc, 10 mA)
M 1
Multi-function relay output (During Run H2-01)
250 Vac, max. 1 A
M 2
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
M 3
Multi-function relay output (Zero Speed H2-02)
250 Vac, max. 1 A
M 4
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
FM
Multi-function analog output 1
(Output frequency)
+
FM
-10 to +10 Vdc (2mA)
or 4 to 20 mA
AM
Multi-function analog output 2
+
AC
(Output current)
AM
-10 to +10 Vdc (2mA)
0 V
or 4 to 20 mA
E (G)
main circuit terminal
3
<10>
<10>
69