YASKAWA P1000 Technical Manual page 303

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

Digital Operator Display
Cause
Option card or hardware is damaged
Digital Operator Display
oFC50 to oFC55
to
Cause
Option card or hardware is damaged
Digital Operator Display
Cause
Surrounding temperature is too high
Load is too heavy
Internal cooling fan is stopped
Digital Operator Display
Cause
Surrounding temperature is too high
Load is too heavy
Digital Operator Display
<1>
Cause
Motor has overheated
<1> Detected in models 4A0930 and 4A1200.
Digital Operator Display
Cause
Load is too heavy
Cycle times are too short during acceleration
and deceleration
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa
representative for instructions on replacing the control board.
Option Card Error Occurred at Option Port CN5-C
Refer to the option manual for details.
Heatsink Overheat
oH
The heatsink temperature exceeded the overheat pre-alarm level set to L8-02. The default value for L8-02
is determined by drive model selection (o2-04).
• Check the temperature surrounding the drive. Verify temperature is within drive specifications.
• Improve the air circulation within the enclosure panel.
• Install a fan or air conditioner to cool the surrounding area.
• Remove anything near the drive that might be producing excessive heat.
• Measure the output current.
• Decrease the load.
• Lower the carrier frequency selection (C6-02).
• Replace the cooling fan.
• After replacing the cooling fan, set parameter o4-03 to 0 to reset the cooling fan maintenance.
Overheat 1 (Heatsink Overheat)
oH1
The heatsink temperature exceeded the drive overheat level. Overheat level is determined by drive
capacity (o2-04).
• Check the temperature surrounding the drive.
• Improve the air circulation within the enclosure panel.
• Install a fan or air conditioner to cool the surrounding area.
• Remove anything near the drive that might be producing excessive heat.
• Measure the output current.
• Lower the carrier frequency selection (C6-02).
• Reduce the load.
Motor Overheat (NTC Input)
oH5
The motor temperature exceeded the level set to L1-16 (or L1-18 for motor 2)
• Reduce the load.
• Check the ambient temperature.
Motor Overload
oL1
The electronic motor overload protection tripped
Reduce the load.
Increase the acceleration and deceleration times (C1-01 through C1-04).
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
6.4 Fault Detection
6
303

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents