YASKAWA P1000 Technical Manual page 116

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

4.3 The Drive, Programming, and Clock Adjustment Modes
3
Press the ENTER key to enter select the parameter setting mode.
4
Use the up and down arrow keys to scroll through display menu until parameter o4-17 appears.
5
Press the ENTER key until "0" flashes.
6
Press the up arrow key so that the display changes to "1".
Press the ENTER key and the time setting screen will appear. Use the right arrow key to select
7
the desired digit, then set the correct date and time using the up and down arrow keys.
After entering the correct time, press the ENTER key to save the changes.
8
The display will return to the display shown in step 5 and the alarm LED will be OFF.
n
o4-17: Real-Time Clock Setting
No.
(Addr.
Name
Hex)
Set/Reset Real-time Clock
o4-17
Set Time
(3100)
Setting 0: — —
No Setting (Default)
Setting 1: Set
When o4-17 is set to 1, the digital operator will show the Clock Adjustment display. In Clock Adjustment Mode the user can
adjust the Real-Time Clock.
Setting 2: Reset
When o4-17 is set to 2, the Real-Time Clock data is cleared. A TIM fault will occur until o4-17 is set to 1 and the Real-Time
Clock is set.
116
Procedure
Sets the current date and time for the Real-Time Clock.
0: — —
0: — — No Setting
1: Set
1: Real-Time Clock Set
2: Reset
2: Real-Time Clock Reset
Description
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Display
ALM
ALM
- PRMSET - PRG
Initialization
A1-00 = 0
Select Language
FWD
HOME
DATA
ALM
ALM
- PRMSET - PRG
Maintenance
o4-17 = 0
Set time
FWD
HOME
DATA
ALM
ALM
- PRMSET - PRG
Set time
o4-17=
0
*0*
- -
"0"
FWD
HOME
DATA
ALM
ALM
- PRMSET - PRG
Set time
o4-17=
1
*0*
Set
"0"
HOME
FWD
DATA
ALM
ALM
YYYY/MM/DD HH:MM
20
1
0/01/01 00:00
Second per month
+ 0 sec
ALM
Entry accepted
Values
Default: 0
Range: 0 to 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents