Defaults By Drive Model - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

B.16 Defaults by Drive Model
The following tables show parameters and default settings that change with the drive model selection (o2-04).
Table B.6 200 V Class Drives Default Settings by Drive Model Selection and ND settings
No.
o2-04
E2-11
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
Output Current 2 during Speed Search
b3-07
(Speed Estimation Type)
b3-26
Start Speed Search Select
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01
Motor Rated Current
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-05
Motor Line-to-Line Resistance
E2-06
Motor Leakage Inductance
E2-10
Motor Iron Loss for Torque Compensation
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Name
Model CIMR-Po
Drive Model Selection
Motor Rated Output
B.16 Defaults by Drive Model
Unit
Default Settings
2A0004
2A0006
Hex.
62
63
0.75
1.1
kW (HP)
(0.75)
(1)
%
100
100
1
0.5
s
0.50
0.50
223.7
196.6
2
0.0028
0.0068
kgm
7
7
A
3.3
4.9
Hz
2.5
2.6
A
1.8
2.3
Ω
5.156
3.577
%
13.8
18.5
W
26
38
s
0.1
0.2
s
0.3
0.4
s
0.3
0.3
s
0.142
0.142
°C
115
115
2
2
2
2
ms
10
10
2A0008
2A0010
64
65
1.5
2.2
(2)
(3)
100
100
0.5
0.5
0.50
0.50
169.4
156.8
0.0068
0.0088
7
7
6.2
8.5
2.6
2.9
2.8
3
1.997
1.601
18.5
18.4
53
77
0.3
0.3
0.4
0.5
0.3
0.3
0.166
0.145
115
115
2
2
2
2
10
10
B
487

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents