B.8 H Parameters: Multi-Function Terminals
No.
(Addr.
Name
Hex)
H6-03
(42E)
Pulse Train Input Gain
H6-04
(42F)
Pulse Train Input Bias
H6-05
(430)
Pulse Train Input Filter Time
H6-08
Pulse Train Input Minimum
(43F)
Frequency
462
Sets the level of the value selected in H6-01 when a frequency with the value
set in H6-02 is input.
Sets the level of the value selected in H6-01 when 0 Hz is input.
Sets the pulse train input filter time constant.
Sets the minimum frequency for the pulse train input to be detected. Enabled
when H6-01 = 0, 1, or 2.
Description
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Values
Page
Default: 100.0%
Min.: 0.0
232
Max.: 1000.0
Default: 0.0%
Min.: -100.0
232
Max.: 100.0
Default: 0.10 s
Min.: 0.00
232
Max.: 2.00
Default: 0.5 Hz
Min.: 0.1
233
Max.: 1000.0