8.2 Drive Options and Peripheral Devices

8.2

Drive Options and Peripheral Devices

Table 8.1
lists the names of the various peripheral devices, accessories, and options available for Yaskawa drives. Contact
Yaskawa or your Yaskawa agent to order these peripheral devices.
• Peripheral Device Selection: Refer to the Yaskawa catalog for selection and part numbers.
• Peripheral Device Installation: Refer to the corresponding option manual for installation instructions.
Option
DC link choke
AC Reactor
Braking Resistor
Analog Monitor
AO-A3
EtherNet/IP
SI-EN3
Modbus TCP/IP
SI-EM3
<1>
SI-EP3
PROFINET
DeviceNet
SI-N3
PROFIBUS-DP
SI-P3
MECHATROLINK-II
SI-T3
BACnet
SI-B3
<2>
SI-C3
CC-Link
<2>
SI-S3
CANopen
UWR000051, 1 m cable
Remote Operator Cable
UWR000052, 2 m cable
USB Copy Unit
JVOP-181
Attachment for External
EZZ020800A/B/C/D
Heatsink
100-054-503
IP20/NEMA Type 1 Kit
100-054-504
IP20/NEMA Type 1, 4, 12
UUX0000526
Blank Keypad Kit
IP20/NEMA Type 1, 4, 12
UUX0000527
Yaskawa Logo Keypad Kit
200 V Class: PS-A10LB
24 V Power Supply
400 V Class: PS-A10HB
600 V Class: PS-A10HB
DriveWizard Industrial
Contact Yaskawa
<1> Available in drive software versions PRG: 8503 and later.
<2> Limited support. Contact a Yaskawa representative or the nearest Yaskawa sales office for assistance.
376
Table 8.1 Available Peripheral Devices
Model Number
Improves the power factor by suppressing harmonic distortion from the power supply.
Protects the drive when operating from a large power supply and improves the power factor by
suppressing harmonic distortion. Highly recommended for power supplies that exceed 600 kVA.
For use with systems that require dynamic braking with up to 3% ED. If higher ED is required,
use a Braking Resistor Unit.
Note:
Input/Output Option Cards
• Provides extra multi-function analog output terminals
• Output channels: 2
• Output voltage: -10 to 10 V, 11-bit (signed)
Communication Option Cards
Connects to an EtherNet/IP network.
Connects to a Modbus TCP/IP network.
Connects to a PROFINET network.
Connects to a DeviceNet network
Connects to a PROFIBUS-DP network.
Connects to a MECHATROLINK-II network.
Connects to a BACnet network.
Connects to a CC-Link network
Connects to a CANopen network.
RJ-45, 8-pin straight through, UTP CAT5e, extension cable (1 m or 2 m) to connect the digital
operator for remote operation.
• Allows the user to copy and verify parameter settings between drives.
• Functions as an adapter to connect the drive to a USB port on a PC.
Installation kit for mounting the drive with the heatsink outside of the panel (Side-by-Side
mounting possible)
Parts to make the drive conform to IP20/NEMA Type 1 enclosure requirements.
Provides digital operator (JVOP-180, JVOP-182) functionality on an enclosure designed for
IP20/NEMA Type 1, 3R, 4, 4X, 12, or IPo6 environment. This keypad has a blank label on the
front.
Provides digital operator (JVOP-180, JVOP-182) functionality on an enclosure designed for
IP20/NEMA Type 1, 3R, 4, 4X, 12, or IPo6 environment. This keypad has a Yaskawa brand
label on the front.
Supplies the drive controller with 24 Vdc power during main power loss.
PC tool for drive setup and parameter management
Power Options
Not rated for 600 V class drive models.
Interface Options
Mechanical Options
Others
PC Software Tools
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Description

Hide quick links:

Advertisement