5.10 o: Operator Related Settings
■
o1-21: Roping Ratio
Sets the roping ratio.
No.
o1-21
Setting 1: 1: 1
Setting 2: 1: 2
Setting 3: 1: 3
Setting 4: 1: 4
■
o1-22: Mechanical Gear Ratio
Sets the gear ratio of the mechanical gear.
No.
o1-22
◆ o2: Digital Operator Keypad Functions
These parameters determine the functions assigned to the operator keys.
■
o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection
Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled or not for switching between
LOCAL and REMOTE.
No.
o2-01
Setting 0: Disabled
The LO/RE key is disabled.
Setting 1: Enabled
The LO/RE switches between LOCAL and REMOTE operation. Switching is possible during stop only. When LOCAL is
selected, the LED indicator on the LO/RE key will light up.
■
o2-02: STOP Key Function Selection
Determines if the STOP key on the digital operator can still be used to stop drive operation when the drive is being
controlled from a remote source (i.e., not from digital operator).
No.
o2-02
Setting 0: Disabled
Setting 1: Enabled
The STOP key will terminate drive operation even if the Up/Down command source is not assigned to the digital
operator. Cycle the Up/Down command to restart the drive if the drive has been stopped by pressing the STOP key.
226
Name
Roping Ratio
Name
Mechanical Gear Ratio
Name
LO/RE Key Function Selection
Name
STOP Key Function Selection
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Setting Range
1 to 4
Setting Range
0.10 to 50.00
Determined by A1-02
Setting Range
0 or 1
Setting Range
0 or 1
Default
2
Default
Default
0
Default
0