No.
Automatic Reduction Selection for Stall Prevention
L3-23
during Run
L3-24
Motor Acceleration Time for Inertia Calculations
L3-25
Load Inertia Ratio
L3-26
Additional DC Bus Capacitors
L3-27
Stall Prevention Detection Time
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L4-03
Speed Agreement Detection Level (+/-)
L4-04
Speed Agreement Detection Width (+/-)
L4-05
Frequency Reference Loss Detection Selection
L4-06
Frequency Reference at Reference Loss
L4-07
Speed Agreement Detection Selection
L5-01
Number of Auto Restart Attempts
L5-02
Auto Restart Fault Output Operation Selection
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
L6-13
Motor Underload Protection Selection
Motor Underload Protection Level at Minimum
L6-14
Frequency
Internal Dynamic Braking Resistor Protection
L8-01
Selection (ERF type)
L8-02
Overheat Alarm Level
L8-03
Overheat Pre-Alarm Operation Selection
L8-05
Input Phase Loss Protection Selection
L8-07
Output Phase Loss Protection
L8-09
Output Ground Fault Detection Selection
L8-10
Heatsink Cooling Fan Operation Selection
L8-11
Heatsink Cooling Fan Off Delay Time
L8-12
Ambient Temperature Setting
L8-15
oL2 Characteristics Selection at Low Speeds
L8-18
Software Current Limit Selection
Frequency Reduction Rate during Overheat
L8-19
Pre-Alarm
Main Contactor and Cooling Fan Power Supply
L8-32
Failure Selection
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
L8-40
Carrier Frequency Reduction Off-Delay Time
L8-41
High Current Alarm Selection
L8-55
Internal Braking Transistor Protection
L8-78
Power Unit Output Phase Loss Protection
L8-93
LSo Detection Time at Low Speed
L8-94
LSo Detection Level at Low Speed
L8-95
Average LSo Frequency at Low Speed
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
User
Name
Setting
No.
Name
n1-01
Hunting Prevention Selection
n1-02
Hunting Prevention Gain Setting
n1-03
Hunting Prevention Time Constant
n1-05
Hunting Prevention Gain while in Reverse
n3-01
High-Slip Braking Deceleration Frequency Width
n3-02
High-Slip Braking Current Limit
n3-03
High-Slip Braking Dwell Time at Stop
n3-04
High-Slip Braking Overload Time
n3-13
Overexcitation Deceleration Gain
High Frequency Injection during Overexcitation
n3-14
Deceleration
n3-21
High-Slip Suppression Current Level
n3-23
Overexcitation Operation Selection
o1-01
Drive Mode Unit Monitor Selection
o1-02
User Monitor Selection After Power Up
o1-03
Digital Operator Display Selection
o1-06
User Monitor Selection Mode
o1-07
Second Line Monitor Selection
o1-08
Third Line Monitor Selection
o1-09
Frequency Reference Display Units
o1-10
User-Set Display Units Maximum Value
o1-11
User-Set Display Units Decimal Display
Frequency Reference and Frequency Related
o1-13
Monitor Custom Units 1
Frequency Reference and Frequency Related
o1-14
Monitor Custom Units 2
Frequency Reference and Frequency Related
o1-15
Monitor Custom Units 3
o2-01
LO/RE Key Function Selection
o2-02
STOP Key Function Selection
o2-03
User Parameter Default Value
o2-04
Drive Model Selection
o2-05
Frequency Reference Setting Method Selection
Operation Selection when Digital Operator is
o2-06
Disconnected
o2-07
Motor Direction at Power Up when Using Operator
o2-20
Operator RUN Save at Power Loss
o3-01
Copy Function Selection
o3-02
Copy Allowed Selection
o4-01
Cumulative Operation Time Setting
o4-02
Cumulative Operation Time Selection
o4-03
Cooling Fan Maintenance Operation Time Setting
o4-05
Capacitor Maintenance Setting
o4-07
DC Bus Pre-charge Relay Maintenance Setting
o4-09
IGBT Maintenance Setting
o4-11
U2, U3 Initialize Selection
o4-12
kWh Monitor Initialization
o4-13
Number of Run Commands Counter Initialization
E.3 User Setting Table