B.12 S: Special Application
No.
(Addr.
Name
Hex)
S3-04
Secondary PI Unit
(321D)
Selection
S3-05
(321E)
Secondary PI Setpoint Value
S3-06
Secondary PI Proportional
(321F)
Gain Setting
S3-07
Secondary PI Integral Time
(3220)
Setting
S3-08
Secondary PI Integral Limit
(3221)
Setting
S3-09
Secondary PI Output Upper
(3222)
Limit
S3-10
Secondary PI Output Lower
(3223)
Limit
S3-11
Secondary PI Output Level
(3224)
Selection
S3-12
(3225)
Secondary PI Disable Mode
S3-13
Secondary PI Low Feedback
(3226)
Detection Level
S3-14
Secondary PI Low Feedback
(3227)
Detection Time
S3-15
Secondary PI High
(3228)
Feedback Level
S3-16
Secondary PI High
(3229)
Feedback Detection Time
S3-17
Secondary PI Feedback
(322A)
Detection Selection
<1> Unit is determined by S3-04.
<2> Upper limit is S3-02, decimal placeholder is determined by S3-03.
476
Sets the units for the secondary PI control function.
0: Inch of water (WC)
1: Pounds per square inch (PSI)
2: Gallons per minute (GPM)
3: Degrees Fahrenheit (F)
4: Cubic feet per minute (CFM)
5: Cubic meters per hour (CMH)
6: Liters per hour (LPH)
7: Liters per second (LPS)
8: Bar (Bar)
9: Pascals (Pa)
10: Degrees Celsius (C)
11: Meters (Mtr) (Ft: Feet)
12: Liters per minute (LPM)
13: Cubic meters per minute (CMM)
14: No unit
15: Percentage (%)
Sets the secondary PI controller target value.
Sets the proportional gain of the secondary PI controller. A setting of 0.00
disables P control.
Sets the integral time for the secondary PI controller. A setting of 0.0 s disables
integral control.
Sets the maximum output possible from the integrator.
Sets the maximum output possible from the secondary PI controller.
Sets the minimum output possible from the secondary PI controller.
Sets the secondary PI controller output direction.
0: Normal Output (direct acting)
1: Reverse Output (reverse acting)
Selects the secondary PI controller output when disabled.
0: No output (0%)
1: Lower Limit (S3-10)
2: Setpoint
Sets the secondary PI low feedback detection level.
Sets the secondary PI low feedback detection delay time in seconds.
Sets the secondary PI high feedback detection level.
Sets the secondary PI high feedback detection delay time in seconds.
Selects when secondary PI controller low and high feedback detection are
active.
0: Secondary PI enabled
1: Always
Description
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Values
Page
Default: 15
282
Range: 0 to 15
<1>
Default: 0.00
Min.: 0.00
282
<2>
Max.: 600.00
Default: 1.00
Min.: 0.00
283
Max.: 25.00
Default: 1.0 s
Min.: 0.0
283
Max.: 360.0
Default: 100.0%
Min.: 0.0
283
Max.: 100.0
Default: 100.0%
Min.: 0.0
283
Max.: 100.0
Default: 0.00%
Min.: -100.00
283
Max.: 100.00
Default: 0
283
Range: 0, 1
Default: 0
283
Range: 0 to 2
<1>
Default: 0.00
Min.: 0.00
283
<2>
Max.: 600.00
Default: 1.0 s
Min.: 0.0
284
Max.: 25.5
<1>
Default: 100.00
Min.: 0.00
284
<2>
Max.: 600.00
Default: 1.0 s
Min.: 0.0
284
Max.: 25.5
Default: 0
284
Range: 0, 1

Hide quick links:

Advertisement

Table of Contents
loading