S6: P1000 Protection; S7: Output Current Limit - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

u

S6: P1000 Protection

No.
(Addr.
Name
Hex)
S6-01
Emergency Override Speed Sets the speed command used in emergency override mode when S6-02 = 0.
(3236)
S6-02
Emergency Override
(3237)
Reference Selection
S6-07
Output Phase Loss Level for
(323C)
Dynamic Noise Control
u

S7: Output Current Limit

No.
(Addr.
Name
Hex)
S7-01
(324B)
Output Current Limit Select
<1>
S7-02
(324C)
Current Limit
<1>
S7-10
Single Phase Foldback
(3250)
Selection
<1>
S7-11
(3251)
Ripple Regulator Setpoint
<1>
<1> Available in drive software versions PRG: 8503 and later.
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Description
Selects the emergency override speed source.
0: Use S6-01 Reference
1: Use Frequency Reference
Reduces the output phase loss level when Dynamic Noise Control is active.
Description
Sets the function to enable and disable the output current regulator.
0: Disabled
1: Enabled
Sets the current limit. The value is internally limited to 300% of drive rated
current.
Sets the function to enable and disable the single-phase ripple regulator.
0: Disabled
1: Enabled
Set as a percentage of the maximum amount of ripple allowed before the drive
will detect and input phase loss fault.
B.12 S: Special Application
Values
Page
Default: 0.00 Hz
Min.: 0.00
Max.: 240.00
Default: 0
Range: 0, 1
Default: 100.0%
Min.: 10.0
Max.: 100.0
Values
Page
Default: 0
Range: 0, 1
Default: 0.0 A
Min.: 0.0
Max.: 1000.0
Default: 1
Range: 0, 1
Default: 95.0%
Min.: 0.0
Max.: 200.0
284
284
285
B