U4: Maintenance Monitors - YASKAWA P1000 Technical Manual

Models: 200 v class: 3/4 to 175 hp nd 400 v class: 3/4 to 1000 hp nd 600 v class: 1 to 250 hp nd
Hide thumbs Also See for P1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
U3-41
Time Hours and Minutes
(301F)
at 7th Most Recent Fault
U3-42
Date Year at 8th Most
(3020)
Recent Fault
U3-43
Date Month and Day 8th at
(3021)
Most Recent Fault
U3-44
Time Hours and Minutes
(3022)
at 8th Most Recent Fault
U3-45
Date Year at 9th Most
(3023)
Recent Fault
U3-46
Date Month and Day at 9th
(3024)
Most Recent Fault
U3-47
Time Hours and Minutes
(3025)
at 9th Most Recent Fault
U3-48
Date Year at 10th Most
(3026)
Recent Fault
U3-49
Date Month and Day at
(3027)
10th Most Recent Fault
U3-50
Time Hours and Minutes
(3028)
at 10th Most Recent
u

U4: Maintenance Monitors

No.
(Addr.
Name
Hex)
U4-01
Cumulative Operation
(4C)
Time
U4-02
Number of Run
(75)
Commands
U4-03
Cooling Fan Operation
(67)
Time
U4-04
Cooling Fan Maintenance
(7E)
U4-05
Capacitor Maintenance
(7C)
U4-06
Soft Charge Bypass Relay
(7D6)
Maintenance
U4-07
IGBT Maintenance
(7D7)
U4-08
Heatsink Temperature
(68)
U4-09
LED Check
(5E)
U4-10
kWh, Lower 4 Digits
(5C)
U4-11
kWh, Upper 5 Digits
(5D)
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Description
Displays the time when the seventh most recent fault occurred.
Displays the year when the eighth most recent fault occurred.
Displays the date and day when the eighth most recent fault occurred.
Displays the time when the eighth most recent fault occurred.
Displays the year when the ninth most recent fault occurred.
Displays the date and day when the ninth most recent fault occurred.
Displays the time when the ninth most recent fault occurred.
Displays the year when the tenth most recent fault occurred.
Displays the date and day when the tenth most recent fault occurred.
Displays the time when the tenth most recent fault occurred.
Description
Displays the cumulative operation time of the drive. The value for the
cumulative operation time counter can be reset in parameter o4-01. Use
parameter o4-02 to determine if the operation time should start as soon as
the power is switched on or only while the Run command is present. The
maximum number displayed is 99999, after which the value is reset to 0.
Displays the number of times the Run command is entered. Reset the
number of Run commands using parameter o4-13. This value will reset to
0 and start counting again after reaching 65535.
Displays the cumulative operation time of the cooling fan. The default value
for the fan operation time is reset in parameter o4-03. This value will reset
to 0 and start counting again after reaching 99999.
Displays main cooling fan usage time as a percentage of its expected
performance life. Parameter o4-03 can be used to reset this monitor.
Replace the fan when this monitor reaches 90%.
Displays main circuit capacitor usage time as a percentage of their expected
performance life. Parameter o4-05 can be used to reset this monitor.
Replace the capacitor when this monitor reaches 90%.
Displays the soft charge bypass relay maintenance time as a percentage of
its estimated performance life. Parameter o4-07 can be used to reset this
monitor.
Replace the soft charge bypass relay when this monitor reaches 90%.
Displays IGBT usage time as a percentage of the expected performance
life. Parameter o4-09 can be used to reset this monitor.
Replace the IGBT when this monitor reaches 90%.
Displays the heatsink temperature.
Lights all segments of the LED to verify that the display is working
properly.
Monitors the drive output power. The value is shown as a 9-digit number
displayed across two monitor parameters, U4-10 and U4-11.
Example:
12345678.9 kWh is displayed as:
U4-10: 678.9 kWh
U4-11: 12345 MWh
B.14 U: Monitors
Analog Output
Unit
Level
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
Analog Output
Unit
Level
No signal output
1 h
available
No signal output
1 Time
available
No signal output
1 h
available
No signal output
1%
available
No signal output
1%
available
No signal output
1%
available
No signal output
1%
available
10 V: 100 °C
1 °C
No signal output
available
No signal output
1 kWh
available
No signal output
1 MWh
available
483